Low Pressure Explosion Proof Refrigerant Recovery Machine CMR123-20 Applies to TICA
Nanjing TICA was founded in 2015, providing design, engineering, energy management, investment and other integrated products and services in the field of thermal energy utilization. Core business is in ORC technology R&D, manufacturing and application development. Their goods can be widely used in iron and steel metallurgy, cement building materials, chemical petroleum, nuclear thermal power, printing and dyeing paper, chemical fertilizer pharmaceutical and waste heat recovery power generation of high energy consumption industries, can be used to converse the wasted low grade heat energy to high quality electric energy.
On-site conditions: 1.4 tons of R245fa refrigerant inside the ORC unit needs to be quickly recovered into the storage tank when the ORC unit is shut down for maintenance, and then recharge R245fa refrigerant into the unit once maintenance is finished. It also needs the refrigerant recovery machine with explosion-proof measures.
Solution: Because R245fa refrigerant with the characteristic of low pressure, it often exists in a liquid state when the temperature is low. If to be recovered quickly, which requires the refrigerant recovery machine with large air displacement. Under this condition, They need the low pressure refrigerant recovery machine CMR123-20, utilizes newly type oil-free compressor, air displacement as 20m³/h and the vacuum reaches -0.09Mpa, meanwhile with explosion-proof design for high safety.
Following-up feedback : good use condition, easy to operate and use. For the larger capacity ORC system, the customer plans to buy larger displacement and faster speed refrigerant recovery machine.